Published On: August 5ᵗʰ, 2019 19:03
Catalyst 6500 Series Switch Content Switching Module Installation Note Software Release 4.2(x)
Product Number: WS-X6066-SLB-APC
This publication describes how to install the Content Switching Module (CSM) in the Catalyst 6500 series switches, including the software and hardware requirements.
Contents
This publication contains these sections:
•
Environmental and System
Requirements
•
Cisco Product Security Overview
•
Obtaining Technical Assistance
•
Obtaining Additional Publications
and Information
Front Panel Description
This section describes the physical attributes of the Content Switching Module.
Figure 1 shows the CSM front panel.
Figure 1 Content Switching Module Front Panel

Note
The RJ-45 connector is covered by a removable plate.
Status LED
At startup, the CSM initializes various hardware components and communicates with the supervisor engine. The Status LED indicates the supervisor engine operations and the initialization results. During the normal initialization sequence, the status LED changes from off to red to orange to and green.
Note
For more information on the supervisor engine LEDs,
refer to the Catalyst
6500 Series Switch Module Installation Guide.
Table 1 describes the Status LED operation.
Table 1 Content Switching Module Status LED
|
Color
|
Description
|
|---|---|
|
Off |
• • • – – |
|
Red |
• • |
|
Orange |
• • • • |
|
Green |
• |
|
Green to orange |
• |
|
1 Enter the show environment temperature mod command to display the temperature of each of four sensors on the CSM. 2 CLI=command-line interface. |
RJ-45 Connector
The RJ-45 connector, which is covered by a removable plate, is used to connect a management station device or a test device. This connector is used by field engineers to perform testing and to obtain dump information.
Environmental and System Requirements
This section describes the environmental and system requirements.
Environmental Requirements
Table 2 lists the environmental requirements for the CSM.
Table 2 CSM Environmental Requirements
System Requirements
Before you install the CSM into the Catalyst 6500 series switch, refer to the Release Notes for Catalyst 6500 Series Content Switching Module to make sure that the switch meets the hardware and software requirements.
Safety Overview
Warning
Only trained and qualified personnel should be allowed
to install, replace, or service this equipment. Statement 1030
Warning
Hazardous voltage or energy is present on the
backplane when the system is operating. Use caution when servicing.
Statement 1034
Warning
Blank
faceplates and cover panels serve three important functions: they
prevent exposure to hazardous voltages and currents inside the
chassis; they contain electromagnetic interference (EMI) that might
disrupt other equipment; and they direct the flow of cooling air
through the chassis. Do not operate the system unless all cards,
faceplates, front covers, and rear covers are in place.
Statement 1029
Warning
During this procedure, wear grounding wrist straps to
avoid ESD damage to the card. Do not directly touch the backplane
with your hand or any metal tool, or you could shock yourself.
Preparing to Install the CSM
Before installing the CSM, make sure that the following items are available:
•
Catalyst 6500 series switch chassis
•
Management station that is available through a Telnet
or a console connection to perform configuration tasks
Required Tools
These tools are required to install the CSM in the Catalyst 6500 series switches:
•
Flat-blade screwdriver
•
Phillips-head screwdriver
•
Wrist strap or other grounding device
•
Antistatic mat or antistatic foam
Whenever you handle the CSM, always use a wrist strap or other grounding device to prevent electrostatic discharge (ESD).
Installing the CSM
Note
All modules, including the supervisor engine (if you
have redundant supervisor engines), support hot swapping. You can
add, replace, or remove modules without interrupting the system
power or causing other software or interfaces to shut down. For
more information about hot-swapping modules, refer to the
Catalyst 6500 Series Switch Module Installation Guide.
Warning
During this procedure, wear grounding wrist straps to
avoid ESD damage to the module. Do not directly touch the backplane
with your hand or any metal tool, or you could shock yourself.
To install a module in the chassis, perform these steps:
Step 1
Choose a slot for the CSM.
Step 2
Verify that there is enough clearance to accommodate
any interface equipment that you will connect directly to the
module ports. If possible, place modules between empty slots that
contain only module filler plates.
Step 3
Verify that the captive installation screws are
tightened on all modules installed in the chassis.
This action ensures that the EMI gaskets on all modules are fully compressed to maximize the opening space for the replacement module.
Note
If the captive installation screws are loose, the EMI
gaskets on the installed modules will push adjacent modules toward
the open slot, reducing the opening size and making it difficult to
install the replacement module.
Step 4
Remove the module filler plate by removing the two
Phillips pan-head screws from the filler plate. (To remove a
module, refer to the "Removing the Module"
section.)
Step 5
Fully open both ejector levers on the new or
replacement module. (See Figure 2.)
Figure 2 Positioning the Module in a Horizontal Slot Chassis

Step 6
Depending on the orientation of the slots in the
chassis (horizontal or vertical), perform one of the following sets
of substeps:
Horizontal slots
a.
Position the module in the slot. Make sure that you
align the sides of the module carrier with the slot guides on each
side of the slot. (See Figure 2.)
b.
Carefully slide the module into the slot until the EMI
gasket along the top edge of the module makes contact with the
module in the slot above it and both ejector levers have closed to
approximately 45 degrees with respect to the module faceplate. (See
Figure 3.)
Figure 3 Clearing the EMI Gasket in a Horizontal Slot Chassis

c.
Using the thumb and forefinger of each hand, grasp the
two ejector levers and press down to create a small (0.040 inch [1
mm]) gap between the EMI gasket and the module above it. (See
Figure 3.)
d.
While pressing down, simultaneously close the left and
right ejector levers to fully seat the module in the backplane
connector. The ejector levers are fully closed when they are flush
with the module faceplate. (See Figure 4.)
Figure 4 Ejector Lever Closure in a Horizontal Slot Chassis

Note
Failure to fully seat the module in the backplane
connector can result in error messages.
e.
Tighten the two captive installation screws on the
module.
Note
Make sure that the ejector levers are fully closed
before tightening the captive installation screws.
Vertical slots
a.
Position the module in the slot. (See Figure 5.) Make sure that you align the sides of the
module carrier with the slot guides on the top and bottom of the
slot.
Figure 5 Positioning the Module in a Vertical Slot Chassis

b.
Carefully slide the module into the slot until the EMI
gasket along the right edge of the module makes contact with the
module in the slot adjacent to it and both ejector levers have
closed to approximately 45 degrees with respect to the module
faceplate. (See Figure 6.)
c.
Using the thumb and forefinger of each hand, grasp the
two ejector levers and exert a slight pressure to the left,
deflecting the module approximately 0.040 inches (1 mm) to create a
small gap between the module's EMI gasket and the module adjacent
to it. (See Figure 6.)
Figure 6 Clearing the EMI Gasket in a Vertical Slot Chassis

d.
While pressing on the ejector levers, simultaneously
close them to fully seat the module in the backplane connector. The
ejector levers are fully closed when they are flush with the module
faceplate. (See Figure 7.)
Figure 7 Ejector Lever Closure in a Vertical Slot Chassis

e.
Tighten the two captive installation screws on the
module.
Note
Make sure that the ejector levers are fully closed
before tightening the captive installation screws.
This completes the CSM installation procedure.
Verifying the Installation
When you install the CSM in a Catalyst 6500 series switch, the module goes through a startup sequence that requires no intervention. At the successful conclusion of the startup sequence, the green Status LED will light and remain on. If the Status LED does not show green, or if it shows a different color, refer to Table 1 to determine the status of the module.
Removing the Module
This section describes how to remove an existing module from a Catalyst 6500 series switch chassis slot.
Warning
Invisible laser radiation may be emitted from
disconnected fibers or connectors. Do not stare into beams or view
directly with optical instruments. Statement 1051
To remove a module from the chassis, perform these steps:
Step 1
Disconnect any network interface cables that are
attached to the module.
Step 2
Verify that the captive installation screws on all of
the modules in the chassis are tight.
This step assures that the space that is created by the removed module is maintained.
Note
If the captive installation screws are loose, the
electromagnetic interference (EMI) gaskets on the installed modules
will push the modules toward the open slot, reducing the opening
size and making it difficult to install the replacement module.
Step 3
Loosen the two captive installation screws on the
module.
Step 4
Depending on the orientation of the slots in the
chassis (horizontal or vertical), perform one of the following sets
of substeps:
Horizontal slots
a.
Place your thumbs on the left and right ejector
levers, and simultaneously rotate the levers outward to unseat the
module from the backplane connector.
b.
Grasp the front edge of the module, and slide the
module part of the way out of the slot. Place your other hand under
the module to support the weight of the module. Do not touch the
module circuitry.
Vertical slots
a.
Place your thumbs on the ejector levers that are
located at the top and bottom of the module, and simultaneously
rotate the levers outward to unseat the module from the backplane
connector.
b.
Grasp the edges of the module, and slide the module
straight out of the slot. Do not touch the module circuitry.
Step 5
Place the module on an antistatic mat or antistatic
foam, or immediately reinstall it in another slot.
Step 6
If the slot from which you removed the module is to
remain empty, install a module filler plate to keep dust out of the
chassis and to maintain proper airflow through the chassis.
Warning
Blank
faceplates and cover panels serve three important functions: they
prevent exposure to hazardous voltages and currents inside the
chassis; they contain electromagnetic interference (EMI) that might
disrupt other equipment; and they direct the flow of cooling air
through the chassis. Do not operate the system unless all cards,
faceplates, front covers, and rear covers are in place.
Statement 1029
Related Documentation
Use this document with the following Cisco documents:
•
Release Notes for the Catalyst 6500 Series Switch
Content Switching Module
•
Catalyst 6500 Series Switch Content Switching Module
Configuration Note
•
Catalyst 6500 Series Switch Content Switching Module
Command Reference
•
Catalyst
6500 Series Switch Cisco IOS Software Configuration Guide
•
Catalyst 6500 Series Switch Software Configuration
Guide
Obtaining Documentation
Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several ways to obtain technical assistance and other technical resources. These sections explain how to obtain technical information from Cisco Systems.
Cisco.com
You can access the most current Cisco documentation at this URL:
http://www.cisco.com/cisco/web/psa/default.html?mode=prod
You can access the Cisco website at this URL:
You can access international Cisco websites at this URL:
http://www.cisco.com/web/siteassets/locator/index.html
Documentation DVD
Cisco documentation and additional literature are available in a Documentation DVD package, which may have shipped with your product. The Documentation DVD is updated regularly and may be more current than printed documentation. The Documentation DVD package is available as a single unit.
Registered Cisco.com users (Cisco direct customers) can order a Cisco Documentation DVD (product number DOC-DOCDVD=) from the Ordering tool or Cisco Marketplace.
Cisco Ordering tool:
http://www.cisco.com/en/US/ordering/index.shtml
Cisco Marketplace:
http://www.cisco.com/go/marketplace/
Ordering Documentation
You can find instructions for ordering documentation at this URL:
http://www.cisco.com/en/US/ordering/index.shtml
You can order Cisco documentation in these ways:
•
Registered Cisco.com users (Cisco direct customers)
can order Cisco product documentation from the Ordering tool:
http://www.cisco.com/en/US/ordering/index.shtml
•
Nonregistered Cisco.com users can order documentation
through a local account representative by calling Cisco Systems
Corporate Headquarters (California, USA) at 408 526-7208 or,
elsewhere in North America, by calling 1 800 553-NETS (6387).
Documentation Feedback
You can send comments about technical documentation to bug-doc@cisco.com.
You can submit comments by using the response card (if present) behind the front cover of your document or by writing to the following address:
Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Cisco Product Security Overview
Cisco provides a free online Security Vulnerability Policy portal at this URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
From this site, you can perform these tasks:
•
Report security vulnerabilities in Cisco products.
•
Obtain assistance with security incidents that involve
Cisco products.
•
Register to receive security information from Cisco.
A current list of security advisories and notices for Cisco products is available at this URL:
If you prefer to see advisories and notices as they are updated in real time, you can access a Product Security Incident Response Team Really Simple Syndication (PSIRT RSS) feed from this URL:
http://www.cisco.com/en/US/products/products_psirt_rss_feed.html
Reporting Security Problems in Cisco Products
Cisco is committed to delivering secure products. We test our products internally before we release them, and we strive to correct all vulnerabilities quickly. If you think that you might have identified a vulnerability in a Cisco product, contact PSIRT:
•
Emergencies — security-alert@cisco.com
•
Nonemergencies — psirt@cisco.com
Tip
We encourage you to use Pretty Good Privacy (PGP) or a
compatible product to encrypt any sensitive information that you
send to Cisco. PSIRT can work from encrypted information that is
compatible with PGP versions 2.x through
8.x.
Never use a revoked or an expired encryption key. The correct public key to use in your correspondence with PSIRT is the one that has the most recent creation date in this public key server list:
http://pgp.mit.edu:11371/pks/lookup?search=psirt%40cisco.com&op=index&exact=on
In an emergency, you can also reach PSIRT by telephone:
•
1 877 228-7302
•
1 408 525-6532
Obtaining Technical Assistance
For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, Cisco Technical Support provides 24-hour-a-day, award-winning technical assistance. The Cisco Technical Support Website on Cisco.com features extensive online support resources. In addition, Cisco Technical Assistance Center (TAC) engineers provide telephone support. If you do not hold a valid Cisco service contract, contact your reseller.
Cisco Technical Support Website
The Cisco Technical Support Website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day, 365 days a year, at this URL:
http://www.cisco.com/cisco/web/support/index.html
Access to all tools on the Cisco Technical Support Website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a user ID or password, you can register at this URL:
http://tools.cisco.com/RPF/register/register.do
Note
Use the Cisco Product Identification (CPI) tool to
locate your product serial number before submitting a web or phone
request for service. You can access the CPI tool from the Cisco
Technical Support Website by clicking the Tools & Resources link under Documentation &
Tools. Choose Cisco Product Identification Tool from the Alphabetical
Index drop-down list, or click the Cisco Product Identification Tool link under Alerts
& RMAs. The CPI tool offers three search options: by product ID
or model name; by tree view; or for certain products, by copying
and pasting show command output. Search
results show an illustration of your product with the serial number
label location highlighted. Locate the serial number label on your
product and record the information before placing a service call.
Submitting a Service Request
Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3 and S4 service requests are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Service Request Tool provides recommended solutions. If your issue is not resolved using the recommended resources, your service request is assigned to a Cisco TAC engineer. The TAC Service Request Tool is located at this URL:
https://tools.cisco.com/RPF/register/register.do
For S1 or S2 service requests or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco TAC engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly.
To open a service request by telephone, use one of the following numbers:
Asia-Pacific: +61 2 8446 7411 (Australia: 1
800 805 227)
EMEA: +32 2 704 55 55
USA: 1 800 553-2447
For a complete list of Cisco TAC contacts, go to this URL:
http://www.cisco.com/en/US/support/tsd_contact_technical_support.html
Definitions of Service Request Severity
To ensure that all service requests are reported in a standard format, Cisco has established severity definitions.
Severity 1 (S1)—Your network is "down," or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your business operation are negatively affected by inadequate performance of Cisco products. You and Cisco will commit full-time resources during normal business hours to resolve the situation.
Severity 3 (S3)—Operational performance of your network is impaired, but most business operations remain functional. You and Cisco will commit resources during normal business hours to restore service to satisfactory levels.
Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or configuration. There is little or no effect on your business operations.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is available from various online and printed sources.
•
Cisco Marketplace provides a variety of Cisco books,
reference guides, and logo merchandise. Visit Cisco Marketplace,
the company store, at this URL:
http://www.cisco.com/go/marketplace/
•
Cisco Press publishes a
wide range of general networking, training and certification
titles. Both new and experienced users will benefit from these
publications. For current Cisco Press titles and other information,
go to Cisco Press at this URL:
•
Packet magazine is the
Cisco Systems technical user magazine for maximizing Internet and
networking investments. Each quarter, Packet delivers coverage of
the latest industry trends, technology breakthroughs, and Cisco
products and solutions, as well as network deployment and
troubleshooting tips, configuration examples, customer case
studies, certification and training information, and links to
scores of in-depth online resources. You can access Packet magazine
at this URL:
http://www.cisco.com/web/about/ac123/ac114/about_cisco_packet_magazine.html
•
iQ Magazine is the
quarterly publication from Cisco Systems designed to help growing
companies learn how they can use technology to increase revenue,
streamline their business, and expand services. The publication
identifies the challenges facing these companies and the
technologies to help solve them, using real-world case studies and
business strategies to help readers make sound technology
investment decisions.
•
Internet Protocol Journal
is a quarterly journal published by Cisco Systems for engineering
professionals involved in designing, developing, and operating
public and private internets and intranets. You can access the
Internet Protocol Journal at this URL:
http://www.cisco.com/web/about/ac123/ac147/about_cisco_the_internet_protocol_journal.html
•
World-class networking training is available from
Cisco. You can view current offerings at this URL:
http://www.cisco.com/web/learning/index.html
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.