Published On: August 5ᵗʰ, 2019 19:05
Catalyst 6500 Series Switch SIP, SSC, and SPA Hardware Installation Guide
Installing and Removing a SIP or SSC
This chapter describes how to install or remove SIPs or SSCs on the Catalyst 6500 Series switch. This chapter contains the following sections:
•
SIP or SSC Installation and Removal
Handling SIPs or SSCs
Each SIP or SSC circuit board is mounted to a metal carrier and is sensitive to electrostatic discharge (ESD) damage. Before you begin installation, read Chapter 4, "Preparing to Install a SIP, SSC, or SPA," for a list of parts and tools required for installation.
When a slot is not in use, a blank filler plate must be installed in the empty slot to allow the router or switch to conform to electromagnetic interference (EMI) emissions requirements and to allow proper airflow across the installed modules. If you plan to install a SIP or SSC in a slot that is not in use, you must first remove the blank filler plate.
Figure 5-1 Handling a SIP

Online Insertion and Removal
The Catalyst 6500 Series switch supports online insertion and removal (OIR) of the SPA interface processor (SIP) or SPA services card (SSC), in addition to each of the shared port adapters (SPAs). Therefore, you can remove a SIP or SSC with its SPAs still intact, or you can remove a SPA independently from the SIP or SSC, leaving the SIP or SSC installed in the switch.
This section includes the following topics on OIR support:
•
Preparing for Online Removal of a
SIP or SSC
•
Verifying Deactivation and
Activation of a SIP or SSC
•
Preparing for Online Removal of a
SPA
•
Verifying Deactivation and
Activation of a SPA
•
Deactivation and Activation
Configuration Examples
Note
For simplicity, any reference to "SIP" in this section
also applies to the SSC.
Preparing for Online Removal of a SIP or SSC
The Catalyst 6500 Series switch supports OIR of the SIP and the SSC. To do this, you can power down a SIP (which automatically deactivates any installed SPAs) and remove the SIP with the SPAs still intact.
Although graceful deactivation of a SIP is preferred using the no power enable module command, the Catalyst 6500 Series switch does support removal of the SIP without deactivating it first. If you plan to remove a SIP, you can deactivate the SIP first, using the no power enable module global configuration command. When you deactivate a SIP using this command, it automatically deactivates each of the SPAs that are installed in that SIP. Therefore, it is not necessary to deactivate each of the SPAs prior to deactivating the SIP.
Either a blank filler plate or a functional SPA should reside in every subslot of a SIP during normal operation.
For more information about the recommended procedures for physical removal of the SIP, refer to the Catalyst 6500 Series Switch SIP, SSC, and SPA Hardware Installation Guide.
Deactivating a SIP or SSC
To deactivate a SIP or SSC and its installed SPAs prior to removal of the SIP, use the following command in global configuration mode:
For more information about chassis slot numbering, refer to the "Identifying Slots and Subslots for SIPs, SSCs, and SPAs" section in this guide.
Reactivating a SIP or SSC
Once you deactivate a SIP or SSC, whether or not you have performed an OIR, you must use the power enable module global configuration command to reactivate the SIP.
If you did not issue a command to deactivate the SPAs installed in a SIP, but you did deactivate the SIP using the no power enable module command, then you do not need to reactivate the SPAs after an OIR of the SIP. The installed SPAs automatically reactivate upon reactivation of the SIP in the switch.
For example, consider the case where you remove a SIP from the switch to replace it with another SIP. You reinstall the same SPAs into the new SIP. When you enter the power enable module command on the switch, the SPAs will automatically reactivate with the new SIP.
To activate a SIP and its installed SPAs after the SIP has been deactivated, use the following command in global configuration mode:
|
Command
|
Purpose
|
|---|---|
|
Router(config)# power enable module slot |
Activates the SIP in the specified slot and its installed SPAs, where: • |
For more information about chassis slot numbering, refer to the "Identifying Slots and Subslots for SIPs, SSCs, and SPAs" section in this guide.
Verifying Deactivation and Activation of a SIP or SSC
To verify the deactivation of a SIP or SSC, enter the show module command in privileged EXEC configuration mode. Observe the Status field associated with the SIP that you want to verify.
The following example shows that the Cisco 7600 SIP-400 located in slot 13 is deactivated. This is indicated by its "PwrDown" status.
Router# show module 13
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
13 0 4-subslot SPA Interface Processor-400 7600-SIP-400 JAB0851042X
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
13 00e0.aabb.cc00 to 00e0.aabb.cc3f 0.525 12.2(PP_SPL_ 12.2(PP_SPL_ Ok
Mod Online Diag Status
--- -------------------
13 PwrDown
To verify activation and proper operation of a SIP, enter the show module command and observe "Ok" in the Status field as shown in the following example:
Router# show module 2
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
2 0 4-subslot SPA Interface Processor-200 7600-SIP-200 JAB074905S1
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
2 0000.0000.0000 to 0000.0000.003f 0.232 12.2(2004082 12.2(2004082 Ok
Mod Online Diag Status
--- -------------------
2 Pass
Preparing for Online Removal of a SPA
The Catalyst 6500 Series switch supports OIR of a SPA independently of removing the SIP or SSC. This means that a SIP can remain installed in the switch with one SPA remaining active, while you remove another SPA from one of the SIP subslots. If you are not planning to immediately replace a SPA into the SIP, then be sure to install a blank filler plate in the subslot. The SIP should always be fully installed with either functional SPAs or blank filler plates.
The interface configuration is retained (recalled) if a SIP or SPA is removed and then replaced with one of the same type. This is not the case if you replace a Cisco 7600-SIP-200 with a Cisco 7600-SIP-400 or vice-versa.
If you are planning to remove a SIP along with its SPAs, then you do not need to follow the instructions in this section. To remove a SIP, see the "Preparing for Online Removal of a SIP or SSC" section.
Deactivating a SPA
Although graceful deactivation of a SPA is preferred using the hw-module subslot shutdown command, the Catalyst 6500 Series switch does support removal of the SPA without deactivating it first. Before deactivating a SPA, ensure that the SIP is seated securely into the slot before pulling out the SPA itself.
Note
If you are preparing for an OIR of a SPA, it is not
necessary to independently shut down each of the interfaces prior
to deactivation of the SPA. The hw-module subslot shutdown command automatically stops
traffic on the interfaces and deactivates them along with the SPA
in preparation for OIR. In similar fashion, you do not need to
independently restart any interfaces on a SPA after OIR of a SPA or
SIP.
To deactivate a SPA and all of its interfaces prior to removal of the SPA, use the following command in global configuration mode:
For more information about chassis slot and SIP subslot numbering, refer to the "Identifying Slots and Subslots for SIPs, SSCs, and SPAs" section in this guide.
Reactivating a SPA
Note
You do not need to reactivate a SPA after an OIR of
either the SIP or a SPA if you did not deactivate the SPA prior to
removal. If the switch is running, then the SPAs automatically
start upon insertion into the SIP or with insertion of a SIP into
the switch.
If you deactivate a SPA using the hw-module subslot shutdown global configuration command and need to reactivate it without performing an OIR, you need to use the no hw-module subslot shutdown global configuration command to reactivate the SPA and its interfaces.
To activate a SPA and its interfaces after the SPA has been deactivated, use the following command in global configuration mode:
Verifying Deactivation and Activation of a SPA
When you deactivate a SPA, the corresponding interfaces are also deactivated. This means that these interfaces will no longer appear in the output of the show interface command.
To verify the deactivation of a SPA, enter the show hw-module subslot all oir command in privileged EXEC configuration mode. Observe the Operational Status field associated with the SPA that you want to verify.
In the following example, the SPA located in subslot 1 of the SIP in slot 2 of the switch is administratively down from the hw-module subslot shutdown command:
Router# show hw-module subslot all oir
Module Model Operational Status
-------------- ------------------ -------------------------
subslot 2/0 SPA-4XOC3-POS ok
subslot 2/1 SPA-4XOC3-ATM admin down
To verify activation and proper operation of a SPA, enter the show hw-module subslot all oir command and observe "ok" in the Operational Status field as shown in the following example:
Router# show hw-module subslot all oir
Module Model Operational Status
-------------- ------------------ -------------------------
subslot 2/0 SPA-4XOC3-POS ok
subslot 2/1 SPA-4XOC3-ATM ok
Deactivation and Activation Configuration Examples
This section provides the following examples of deactivating and activating SIPs and SPAs:
•
Deactivation of a SIP
Configuration Example
•
Activation of a SIP Configuration
Example
•
Deactivation of a SPA
Configuration Example
•
Activation of a SPA Configuration
Example
Deactivation of a SIP Configuration Example
Deactivate a SIP when you want to perform OIR of the SIP. The following example deactivates the SIP that is installed in slot 5 of the switch, its SPAs, and all of the interfaces. The corresponding console messages are shown:
Router# configure terminal
Router(config)# no power enable module 5
1w4d: %OIR-6-REMCARD: Card removed from slot 5, interfaces disabled
1w4d: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request)
Activation of a SIP Configuration Example
Activate a SIP if you have previously deactivated it. If you did not deactivate the SPAs, the SPAs automatically reactivate with reactivation of the SIP.
The following example activates the SIP that is installed in slot 5 of the switch, its SPA, and all of the interfaces (as long as the hw-module subslot shutdown command was not issued to also deactivate the SPA):
Router# configure terminal
Router(config)# power enable module 5
Notice that there are no corresponding console messages shown with activation. If you re-enter the power enable module command, a message is displayed indicating that the module is already enabled:
Router(config)# power enable module 5
% module is already enabled
Deactivation of a SPA Configuration Example
Deactivate a SPA when you want to perform OIR of that SPA. The following example deactivates the SPA (and its interfaces) that is installed in subslot 0 of the SIP located in slot 2 of the switch and removes power to the SPA. Notice that no corresponding console messages are shown:
Router# configure terminal
Router(config)# hw-module subslot 2/0 shutdown unpowered
Activation of a SPA Configuration Example
Activate a SPA if you have previously deactivated it. If you have not deactivated a SPA and its interfaces during OIR of a SIP, then the SPA is automatically reactivated upon reactivation of the SIP.
The following example activates the SPA that is installed in slot 2 of the switch and all of its interfaces. The corresponding console message is shown:
Router# configure terminal
Router(config)# no hw-module subslot 2/0 shutdown
Router#
SIP or SSC Installation and Removal
This section provides step-by-step instructions for installing and removing a SIP or SSC.
Note
For simplicity, any reference to "SIP" in this section
also applies to the SSC.
Note
To ensure compliance with electromagnetic interference
(EMI) approvals by providing a tight EMI-preventive seal for the
Catalyst 6500 Series switch, we recommend that you first install
SIPs in the slots closest to the supervisor engine slots, and then
work out to the slots furthest from the supervisor engine slots.
Warning
When performing the following procedures, wear a
grounding wrist strap to avoid ESD damage to the SIP. Some
platforms have an ESD connector for attaching the wrist strap. Do
not directly touch the midplane or backplane with your hand or any
metal tool, or you could shock yourself.
To install and remove a SIP, refer to Figure 5-2 and do the following:
Step 1
To insert the SIP, carefully align the edges of the
SIP between the upper and lower edges of the module slot, as shown
in C of Figure 5-2.
Step 2
Carefully slide the SIP halfway into the module slot
and connect all cables to the SPA.
Step 3
With the cables connected, carefully slide the SIP
into the module slot until the SIP makes contact with the
backplane.
Note
The SIP ejector levers must be positioned at a
45-degree angle before the SIP makes contact with the backplane.
Step 4
Push the SIP ejector levers in until the SIP is fully
seated in the router backplane.
Note
When the chassis is fully populated, seating a SIP can
be difficult. To properly seat the SIP and avoid physical damage,
loosen the locking thumbscrews on the neighboring SIPs or line
cards.
Caution
Step 5
Tighten the locking thumbscrews on both sides of the
SIP to a torque of between 8.3 and 11 inch-pounds (94 to 124 N-cm).
Do not overtighten.
Step 6
To remove the SIP, loosen the locking thumbscrews on
both sides of the SIP, as shown in A of Figure
5-2.
Step 7
Pull out the SIP ejector levers, as shown in B of
Figure 5-2, and carefully slide the SIP
halfway out of the module slot. If you are removing a blank filler
plate, pull the blank filler plate completely out of the module
slot.
Step 8
With the SIP halfway out of the module slot,
disconnect all cables from the SPA. After disconnecting the cables,
pull the SIP out of the module slot.
Figure 5-2 illustrates how to install and remove a SIP: