Published On: August 5ᵗʰ, 2019 19:03
Catalyst 6500 Series SSL Services Module Installation and Configuration Note, 1.1
Installing and Removing the SSL Services Module
This chapter describes how to install the SSL Services Module into the Catalyst 6500 series switch and contains these sections:
•
Installing the SSL Services
Module
•
Removing the SSL Services
Module
System Requirements
Before you install the SSL Services Module into the Catalyst 6500 series switch, make sure that the switch meets the hardware and software requirements listed in Table 2-1.
Table 2-1 System Requirements
Safety Overview
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement.
Warning
This warning symbol means danger. You are in a situation that could cause
bodily injury. Before you work on any equipment, be aware of the
hazards involved with electrical circuitry and be familiar with
standard practices for preventing accidents. To see translations of
the warnings that appear in this publication, refer to
the Regulatory Compliance and Safety Information
document that accompanied this device.
Warning
Before you install, operate, or service the system,
read the Site Preparation and Safety Guide. This guide
contains important safety information you should know before
working with the system.
Warning
Only trained and qualified personnel should be allowed
to install, replace, or service this equipment.
Warning
During this procedure, wear grounding wrist straps to
avoid ESD damage to the card. Do not directly touch the backplane
with your hand or any metal tool, or you could shock yourself.
Warning
Blank faceplates and cover panels serve three
important functions: they prevent exposure to hazardous voltages
and currents inside the chassis; they contain electromagnetic
interference (EMI) that might disrupt other equipment; and they
direct the flow of cooling air through the chassis. Do not operate
the system unless all cards, faceplates, front covers, and rear
covers are in place.
Installing the SSL Services Module
The following sections describe how to install the SSL Services Module into the Catalyst 6500 series switch:
•
Preparing to Install the SSL
Services Module
•
Installing the SSL Services
Module
Preparing to Install the SSL Services Module
Before installing the SSL Services Module, make sure that the following items are available:
•
Catalyst 6500 series switch chassis
•
Management station that is available through a Telnet
or a console connection to perform configuration tasks
Required Tools
Warning
Only trained and qualified personnel should be allowed
to install, replace, or service this equipment.
These tools are required to install the SSL Services Module into the Catalyst 6500 series switch:
•
Flat-blade screwdriver
•
Wrist strap or other grounding device
•
Antistatic mat or antistatic foam
Installing the SSL Services Module
Note
Before installing the SSL Services Module, you must
install the Catalyst 6500 series switch chassis and at least one
supervisor engine. For information on installing the switch
chassis, refer to the Catalyst 6500 Series Installation Guide.
This section describes how to install the SSL Services Module into the Catalyst 6500 series switch.
Note
All modules, including the supervisor engine (if you
have redundant supervisor engines), support hot swapping. You can
add, replace, or remove modules without interrupting the system
power or causing other software or interfaces to shut down. For
more information about hot-swapping modules, refer to the Catalyst
6500 Series
Module Installation Guide.
Warning
During this procedure, wear grounding wrist straps to
avoid ESD damage to the card. Do not directly touch the backplane
with your hand or any metal tool, or you could shock yourself.
To install the SSL Services Module into the Catalyst 6500 series switch, perform these steps:
Step 1
Make sure that you take the necessary precautions to
prevent ESD damage.
Step 2
Choose a slot for the SSL Services Module. See
Figure 2-1 for the slot numbers on a
Catalyst 6500 series switch.
Note
Slot 1 is reserved for the supervisor engine. Slot 2
can contain an additional supervisor engine in case the supervisor
engine in slot 1 fails. If a redundant supervisor engine is not
required, you can insert the module in slots 2 through 6 on a
6-slot chassis, slots 2 through 9 on the 9-slot chassis, or slots 2
through 13 on the 13-slot chassis.
Figure 2-1 Slot Numbers on Catalyst 6500 Series Switches

Step 3
Check that there is enough clearance to accommodate
any interface equipment that you will be connecting directly to the
supervisor engine or switching module ports.
Note
If possible, place switching modules between the empty
slots that contain only switching-module filler plates (Cisco part
number 800-00292-01).
Warning
Blank faceplates (filler panels) serve three important
functions: they prevent exposure to hazardous voltages and currents
inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of
cooling air through the chassis. Do not operate the system unless
all cards and faceplates are in place.
Step 4
Loosen the captive installation screws that secure the
switching module filler plate (or an existing switching module) to
the desired slot.
Step 5
Remove the switching module filler plate (or an
existing switching module).
Step 6
Hold the handle of the SSL Services Module with one
hand, and place your other hand under the carrier support. Do not
touch the printed circuit boards or connector pins.
Step 7
Place the SSL Services Module in the slot. Align the
notch on the sides of the switching module carrier with the groove
in the slot. (See Figure 2-2.)
Figure 2-2 Installing Modules in the Catalyst 6500 Series Switch

Step 8
Keep the SSL Services Module at a 90-degree angle to
the backplane and carefully slide the SSL Services Module into the
slot until the switching module faceplate contacts the ejector
levers. (See Figure 2-3.)
Figure 2-3 Ejector Levers and Captive Installation Screws

Step 9
Using the thumb and forefinger of each hand,
simultaneously push in the left and right levers to fully seat the
SSL Services Module in the backplane connector.
Note
If you perform a hot swap, the console displays the
message "Module n has been inserted." This message does not
appear if you are connected to the Catalyst 6500 series switch
through a Telnet session.
Step 10
Use a screwdriver to tighten the captive installation
screws on the left and right ends of the SSL Services Module.
This completes the SSL Services Module installation procedure.
Verifying the Installation
When you install the SSL Services Module into the Catalyst 6500 series switch, the module goes through a boot sequence that requires no intervention. At the successful conclusion of the boot sequence, the green STATUS LED will light and remain on. If the STATUS LED is not green, or is a different color, see Table 1-2 to determine the module's status.
Removing the SSL Services Module
This section describes how to remove the SSL Services Module from the Catalyst 6500 series switch.
Warning
During this procedure, wear grounding wrist straps to
avoid ESD damage to the card. Do not directly touch the backplane
with your hand or any metal tool, or you could shock yourself.
To remove the SSL Services Module, perform these steps:
Step 1
Shut down the module by one of these methods:
•
In privileged mode from the router prompt, enter the
hw-mod module mod shutdown command.
Note
If you enter this command to shut down the module, you
will have to enter the following commands in config mode to restart
(power down, adn then power up) the module:
Router# no power enable module mod
Router# power enable module mod
•
If the module does not respond to any commands, use a
small pointed object to access the SHUTDOWN button, which is
located on the front panel of the module.
Note
Shutdown may require several minutes.
Step 2
Verify that the SSL Services Module shuts down. Do not
remove the module from the switch until the STATUS LED is off or
orange.
Step 3
Use a screwdriver to loosen the captive installation
screws at the left and right sides of the module.
Step 4
Grasp the left and right ejector levers.
Simultaneously, pull the left lever to the left and the right lever
to the right to release the module from the backplane connector.
Step 5
As you pull the module out of the slot, place one hand
under the carrier to support it. Avoid touching the module itself.
Step 6
Carefully pull the module straight out of the slot,
keeping one hand under the carrier to guide it. Keep the module at
a 90-degree orientation to the backplane (horizontal to the floor).
Step 7
Place the removed module on an antistatic mat or
antistatic foam.
Warning
Blank faceplates and cover panels serve three
important functions: they prevent exposure to hazardous voltages
and currents inside the chassis; they contain electromagnetic
interference (EMI) that might disrupt other equipment; and they
direct the flow of cooling air through the chassis. Do not operate
the system unless all cards, faceplates, front covers, and rear
covers are in place.
Step 8
If the slot is to remain empty, install a module
filler plate to keep dust out of the chassis and to maintain proper
airflow through the module compartment.